APC UPS Backup Battery 1100VA 230V / BX1100CI
Lead time | Usually in Stock |
---|
Run time for load
WMin-max: 66-660 W
|
2min 23s |
---|---|
|
|
Main Input Voltage | 230 V |
Main Output Voltage | 230 V |
rated power in W | 660 W |
rated power in VA | 1100 VA |
plug standard | IEC 60320 C14 NEMA 5-15P |
nb of power socket outlets | 2 IEC 60320 C13 4 universal receptacle |
cable length | 1.22 m |
number of cables | 2 |
battery type | Lead-acid battery |
provided equipment | 1, detachable 1.2 m IEC power cord 1, detachable 2.0 m NEMA 5-15P to IEC C13 power cord |
---|---|
product web sub-family | Entry level |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
redundant | No |
height | 21.5 cm |
---|---|
width | 13 cm |
depth | 33.6 cm |
net weight | 12 kg |
mounting preference | No preference |
mounting mode | Not rack-mountable |
two post mountable | 0 |
USB compatible | No |
network frequency | 50/60 Hz +/- 3 Hz auto-sensing |
---|---|
input voltage limits | 150...280 V |
maximum input current | 5 A |
switching current capacity | 10 A |
input current | 5 A (1 phase) |
Maximum configurable power in W | 660 W |
---|---|
output frequency | 50/60 Hz +/- 3 Hz sync to mains 50/60 Hz +/- 1 Hz unsynchronised |
UPS type | Line interactive |
Wave type | Stepped approximation to a sinewave |
Maximum configurable power in VA | 1100 VA |
Transfer time | 8 ms typical : 10 ms maximum |
equipment protection policy | No EPP for ASEAN |
---|
ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
operating altitude | 0...10000 ft |
ambient air temperature for storage | -15…40 °C |
storage Relative Humidity | 0…95 % |
storage altitude | 0.00…9144.00 m |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
number of battery filled slots | 0 |
number of battery free slots | 0 |
Battery recharge time | 8 h |
battery charger power | 19 W rated |
Battery power in VAH | 156 VAh runtime |
battery life | 2…4 year(s) |
extended runtime | 0 |
control panel | LED status display with on line : on battery : replace battery and building wiring fault |
---|---|
alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge energy rate | 273 J |
---|---|
noise suppression | Full time multi-pole noise filtering : 10% of IEEE surge let-through : zero clamping response time: instantaneous |
Data line protection | RJ11 modem/fax protection |
Package 1 Weight | 13 kg |
---|---|
Package 1 Height | 29.5 cm |
Package 1 width | 24.5 cm |
Package 1 Length | 44 cm |
SCC14 | 10731304303197 |
Number of Units in Package 2 | 2 |
Package 2 Weight | 25.90 kg |
Package 2 Height | 330.20 mm |
Package 2 width | 406.40 mm |
Package 2 Length | 508.00 mm |
Number of Units in Package 3 | 32 |