schneider / VDICD62X218 /  U/FTP 23AWG LSZH  Euro class 550MHz 500M Cat6A Roll

schneider / VDICD62X218 / U/FTP 23AWG LSZH Euro class 550MHz 500M Cat6A Roll

  • LE 16,000.00
    Unit price per 
Shipping calculated at checkout.


Specifications

Main

range

Actassi

product or component type

Copper cable

cable packaging

Drum of 500 m

colour tint

Blue

cable shielding type

U/FTP

 

Complementary

type of cable

4 pair cables

communication network category

6A

remote powering

PoE 15W (Power over Ethernet)
PoE+ 30W (Power over Ethernet Plus)
4PPoE 100W (Power over Ethernet)

communication network type

10GBASE-T

minimum return loss

Guaranteed: 20.1 dB at 100 MHz typical: 24.2 dB
Guaranteed: 17.3 dB at 250 MHz typical: 22 dB
Guaranteed: 17.3 dB at 500 MHz typical: 20.3 dB

attenuation

Guaranteed: 19.1 dB Typical: 17.5 dB @ 100 MHz
Guaranteed: 31.1 dB Typical: 28.4 dB @ 250 MHz
Guaranteed: 45.3 dB Typical: 41.4 dB @ 500 MHz

power sum near-end crosstalk [PSNEXT]

Guaranteed: 62.3 dB Typical: 71.0 dB at 100 MHz
Guaranteed: 56.3 dB Typical: 64.2 dB at 250 MHz
Guaranteed: 51.8 dB Typical: 59.1 dB at 500 MHz

attenuation to Crosstalk Ratio Far-end [ACRF]

Guaranteed: 38 dB Typical: 54.7 dB at 100 MHz
Guaranteed: 30 dB Typical: 46.6 dB at 250 MHz
Guaranteed: 24 dB Typical: 40.5 dB at 500 MHz

power sum attenuation crosstalk ratio far-end [PSACRF]

35 dB at 100 MHz
27 dB at 250 MHz
21 dB at 500 MHz

near end crosstalk [NEXT]

Guaranteed: 65.3 dB Typical: 85.5 dB at 100 MHz
Guaranteed: 59.3 dB Typical: 83.1 dB at 250 MHz
Guaranteed: 54.8 dB Typical: 60.1 dB at 500 MHz

coupling attenuation

>= 55 dB from 30…100 MHz conforming to IEC 61156-5, ed. 2 type II
>= 55 - 20 x log10(f / 100) dB from 100…1000 MHz conforming to IEC 61156-5, ed. 2 type II

transfer impedance

<= 50 mOhm/m at 1 MHz (grade 2)
<= 1000 mOhm/m at 100 MHz (grade 2)

input impedance

100 Ohm

segregation class

Class c conforming to EN 50174-2

pulling force

120 N

bending radius

Minimum bending radius during installation: 8 x overall diameter
Minimum bending radius after installation: 4 x overall diameter

material

Solid bare copper: conductor
PE (polyethylene): wire insulation
Aluminium/polyester: foil
Tinned copper: drain wire
PE (polyethylene): sheath

euroclass level

Dca s2 d2 a1

nominal velocity propagation

76 %

AWG gauge

AWG 23

calorific value

547 MJ/km

cable outer diameter

7.6 mm

cable length

500 m

cable weight

49 kg / 1 km

 

Environment

ambient air temperature for installation

0…50 °C

ambient air temperature for storage

-20…60 °C

ambient air temperature for operation

-20…60 °C

directives

2006/95/EC - low voltage directive
305/2011/EU - construction product regulation

flame retardance

LSZH

standards

ISO/IEC 11801-ed. 3 performance
EN 50173-1 performance
EN 50174-1 performance
ANSI/TIA/EIA-568-C.2 performance
IEC 61156-5-ed. 2.1 performance
EN 50288-10-1 performance
ISO/IEC 14763-2 installation standards
EN 50174-2 installation standards
IEC 60332-1 flame propagation characteristics
IEC 60754-1
IEC 60754-2 acidity of combustion gases
IEC 61034 smoke generation

 