JL262A Specification
|
Type
|
Aruba 2930F 48G PoE+ 4SFP Switch
|
System specifications
|
I/O ports and slots
|
48 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+) Duplex: 10BASE-T/100BASETX: half or full 1000BASE-T: full only
|
Additional ports and slots
|
1 dual-personality (RJ-45 or USB micro-B) serial console port
|
Memory and processor
|
Dual Core ARM Coretex @ 1016 MHz, 1 GB DDR3 SDRAM
Packet buffer size: 12.38 MB 4.5MB Ingress/7.875MB Egress, 4 GB eMMC
|
Management
|
Aruba AirWave Network Management; IMC – Intelligent Management Center
Command-line interface
Web browser
Configuration menu
SNMP manager
Telnet
RMON1
FTP
Out-of-band management (serial RS-232C or micro USB)
|
Performance specifications
|
1000 Mb Latency
|
< 3.8 μs (64-byte packets)
|
10 Gbps Latency
|
N/A
|
Throughput
|
up to 77.4 Mp/s
|
Switching capacity
|
104 Gb/s
|
Routing table size
|
10000 entries (IPv4), 5000 entries (IPv6)
|
MAC address table size
|
32768 entries
|
Physical specifications
|
Dimensions
|
4.39 x 44.25 x 30.42 cm ( 1.73 x 17.42 x 11.98 in)
1U height
|
Electrical specifications
|
80plus.org Certification
|
Silver
|
Description
|
N/A
|
Maximum heat dissipation
|
1652.13 kJ/hr (1566 BTU/hr )
|
Voltage
|
100 - 127 / 200 - 240 V ac, rated
|
Current
|
5.1/2.5 A
|
Maximum power rating
|
459 W
|
Idle power
|
48.6 W
|
Frequency
|
50/60 Hz
|
PoE power
|
370 W PoE+
|
Environmental specifications
|
Operating temperature
|
0°C to 45°C (32°F to 113°F)
up to 5000 Feet
- 0C to 40C (32F to 104F) up to 10000 Feet
|
Operating relative humidity
|
15% to 95% @ 40°C ( 104°F)
noncondensing
|
Nonoperating/Storage temperature
|
-40°C to 70°C (-40°F to 158°F)
up to 15000 Feet
|
Nonoperating/Storage temperature
|
15% to 95% @65°C ( 149°F)
noncondensing
|
Acoustic
|
Power: 55.7 dB, Pressure: 41.7 dB
|
Airflow direction
|
Side-to-side
|
Safety certifications
|
Safety
|
UL 60950-1, 2nd Edition
EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011+A2:2013
IEC 60950-1:2005 +A1:2009 +A2:2013
CSA 22.2 No. 60950-1-07 2nd
EN 60825-1:2007 / IEC 60825-1:2007 Class 1
|
Emissions
|
EN 55022:2010/CISPR 22 Class A
FCC CFR 47 Part 15 Class A
VCCI Class A; ICES-003 Class A
CNS 13438
|
Immunity
|
Generic:EN 55024:2010/CISPR 24
ESDIEC 61000-4-2
RadiatedIEC 61000-4-3
EFT/BurstIEC 61000-4-4
SurgeIEC 61000-4-5
ConductedIEC 61000-4-6
Power frequency magnetic fieldIEC 61000-4-8
Voltage dips and interruptionsIEC 61000-4-11
HarmonicsIEC/EN 61000-3-2
FlickerIEC/EN 61000-3-3
|